×ðÁú¿­Ê±

²úƷͼƬ²úÆ·¼ò½éÒªº¦ÌØÕ÷ÐÔÄܲÎÊý»úе³ß´ç¶©¹ºÐÅÏ¢×ÊÁÏÏÂÔØ
·¢ËÍѯÅÌ
SICOM3306
6+3G¶Ë¿Ú¶þ²ãÍø¹ÜÐÍ¿¨¹ìʽ½»Á÷»ú
²úÆ·¼ò½é

SICOM3306Íø¹ÜÐͽ»Á÷»úÊÇÒ»¿îÂÌÉ«¹¤ÒµÒÔÌ«Íø²úÆ·£¬×î¶àÖ§³Ö3¸öǧÕ×SFP¹â¿ÚºÍ6¸ö°ÙÕ×½Ó¿Ú¡£SICOM3306Ö§³ÖDT-RingЭÒé×å(×ÔÓúʱ¼ä<50ms)£¬DRP/DHP£¨×ÔÓúʱ¼ä<20ms£©£¬RSTP£¬VLAN£¬×é²¥£¬QoS£¬SSH£¬ SSLµÈ¸»ºñ¶þ²ãÈí¼þÌØÕ÷£¬²¢Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ¡£SICOM3306¾ßÓÐIP40·À»¤µÄ½ðÊôÍâ¿Ç£¬¿¹Ç¿Õñ¶¯µÄ¿¨¹ì×ù£¬-40¡æ-+85¡æ¼«¶ËÇéÐÎζÈ˳ӦÄÜÁ¦¼°ÓÅÒìµÄEMCµç´Å¼æÈÝÐÔÄÜ£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦¡£¸Ã²úÆ·ÒÑͨ¹ýCE£¬ FCC£¬UL508£¬CID2ÈÏÖ¤£¬ÏÖÔÚÒÑÆÕ±éÓ¦ÓÃÓÚ·çµç£¬ÅäÍø£¬½»Í¨£¬Ê¯ÓÍʯ»¯µÈ¹¤ÒµÁìÓò¡£

Òªº¦ÌØÕ÷

 

ÐÔÄܲÎÊý
Èí¼þ¹¦Ð§
½»Á÷¹¦Ð§ Ö§³ÖVLAN, PVLAN
Ö§³ÖGVRP
Ö§³Ö¶Ë¿Ú¾ÛºÏ
Ö§³Ö¶Ë¿ÚÁ÷¿Ø
Ö§³Ö¶Ë¿ÚÏÞËÙ
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
ÈßÓàÊÖÒÕ Ö§³ÖDT-Ring, DT-Ring+, DT-VLANЭÒé×壬×ÔÓúʱ¼ä<50ms
Ö§³ÖDRP/DHP,×ÔÓúʱ¼ä<20ms
Ö§³ÖSTP/RSTP
×é²¥ÊÖÒÕ Ö§³ÖIGMP Snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
Çå¾²ÊÖÒÕ Ö§³ÖHTTPs/SSL
Ö§³ÖSSH
Ö§³ÖTACACS+
Ö§³ÖIEEE802.1X
Ö§³Ö¶Ë¿ÚMACµØÖ·°ó¶¨
·þÎñÖÊÁ¿¹ÜÀí Ö§³ÖSP£¬WRRÐÐÁе÷Àí
¹ÜÀíÓëά»¤ Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨
Ö§³ÖSNMPv1/v2c/v3,¿Éͨ¹ýKyvision¼¯ÖйÜÀí
Ö§³ÖFTP/TFTPÈí¼þÉý¼¶
Ö§³ÖµçÔ´¸æ¾¯,¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯
Ö§³Ö»·Â·¼ì²â
Ö§³ÖCRC±£»¤
Ö§³ÖRMON
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖÏßÀ¹ÊÕϼì²â
Ö§³ÖSyslog
Ö§³ÖLLDP
Ö§³ÖLink-check
IP¹ÜÀí Ö§³ÖDHCP server/snooping/client, DHCP Option 82
ʱÖÓ¹ÜÀí Ö§³ÖSNTP Client
²úÆ·¹æ¸ñ
±ê×¼ IEEE 802.3i (10Base-T)
IEEE 802.3u (100Base-TXºÍ100Base-FX)
IEEE 802.3z (1000Base-SX/LX)
IEEE802.3x (Á÷¿Ø)
IEEE 802.1p (ÓÅÏȼ¶)
IEEE 802.1Q (VLAN)
IEEE 802.1w (RSTP)
IEEE802.1X
½»Á÷ÊôÐÔ ÓÅÏȼ¶ÐÐÁÐ 4
VLANÊý 256
VLAN ID 1¡«4093
×é²¥×éÊý 256
MAC±í 8K
°ü»º³åÇø 1Mbit
°üת·¢ÂÊ 5.3Mpps
½»Á÷ÑÓ³Ù <5¦Ìs
½Ó¿Ú ǧÕ×¶Ë¿Ú 1000Base-X, SFP½Ó¿Ú
°ÙÕ×¶Ë¿Ú 100Base-FX, µ¥/¶àÄ£, SC/ST/FCÈÎÑ¡; 10/100Base-T(X), RJ45½Ó¿Ú
Console¿Ú Mini USB½Ó¿Ú
¸æ¾¯¶Ë¿Ú 3о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max,2A Max
ָʾµÆ Ç°Ãæ°åָʾµÆ
ÔËÐÐָʾµÆ:Run
¸æ¾¯Ö¸Ê¾µÆ:Alarm
µçԴָʾµÆ:PWR1,PWR2
»·Ö¸Ê¾µÆ:Ring
½Ó¿ÚָʾµÆ:Link/ACT,Speed(µç¿Ú);Link/ACT(¹â¿Ú)
°´Å¥ Reset:Ö§³ÖÖØÆôºÍ»Ö¸´Ä¬ÈÏÉèÖÃ
µçÔ´ ÊäÈëµçѹ 24-48VDC(18-72VDC); 12-24VDC(9-36VDC)
½ÓÈë¶Ë×Ó 5о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó
¹¦ÂÊ <9.1W
¹ýÔر£»¤ Ö§³Ö
·´½Ó±£»¤ Ö§³Ö
ÈßÓà±£»¤ Ö§³Ö
»úе½á¹¹ Íâ¿Ç ½ðÊô²ÄÖÊ
É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ
·À»¤Æ·¼¶ IP40
³ß´ç 53.6mm¡Á135mm¡Á106.5mm(W¡ÁH¡ÁD)
ÖØÁ¿ 0.76Kg
×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ
ÇéÐÎ ÊÂÇéÎÂ¶È -40¡æ¡«+85¡æ
Öü´æÎÂ¶È -40¡æ¡«+85¡æ
Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶
Öʱ£ MTBF 410000h
±£ÐÞÆÚ 5Äê
ÈÏÖ¤ UL508, Class I Div 2, CE(EMC), FCC: ½ÓÄÉL2:24-48VDCµçÔ´µÄÐͺÅ.
UL508, Class I Div 2: ½ÓÄÉL5:12-24VDCµçÔ´µÄÐͺÅ.
ÐÐÒµ±ê×¼ EMI
FCC CFR47 Part 15,EN55022/CISPR22,Class A

EMS
IEC61000-4-2(ESD) ¡À8kV(contact),¡À15kV(air)
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
IEC61000-4-4(EFT) Power Port:¡À4kV;Data Port:¡À2kV
IEC61000-4-5(Surge) Power Port:¡À2kV/DM,¡À4kV/CM;Data Port:¡À2kV
IEC61000-4-6(CS) 10V(150kHz¡«80MHz)

»úе
IEC60068-2-6(Õñ¶¯)
IEC60068-2-27(¹¥»÷)
IEC60068-2-32(×ÔÓɵøÂä)
»úе³ß´ç

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

ÍƼöÐͺÅ

²úÆ·ÐͺÅ

SICOM3306-Ports-Connector-PS1-PS2

´úÂë½ç˵

´úÂëÑ¡ÐÍ

Ports:¶Ë¿Ú

3GX6T=3×1000Base-X, SFP½Ó¿Ú;6×10/100Base-T(X) RJ45µç¿Ú

2GX6T=2×1000Base-X, SFP½Ó¿Ú;6×10/100Base-T(X) RJ45µç¿Ú

1GX8T=1×1000Base-X, SFP½Ó¿Ú;8×10/100Base-T(X) RJ45µç¿Ú

1GX2S6T=1×1000Base-X, SFP½Ó¿Ú; 2×100Base-FX,µ¥Ä£¹â¿Ú; 6×10/100Base-T(X) RJ45µç¿Ú

1GX2M6T=1×1000Base-X, SFP½Ó¿Ú; 2×100Base-FX,¶àÄ£¹â¿Ú; 6×10/100Base-T(X) RJ45µç¿Ú

Connector:°ÙÕ×¹â¿Ú²ÎÊý

SC05=SCÌÖÂÛ,¶àÄ£,1310nm,5km

ST05=STÌÖÂÛ,¶àÄ£,1310nm,5km

FC05=FCÌÖÂÛ,¶àÄ£,1310nm,5km

SC40=SCÌÖÂÛ,µ¥Ä£,1310nm,40km

ST40=STÌÖÂÛ,µ¥Ä£,1310nm,40km

FC40=FCÌÖÂÛ,µ¥Ä£,1310nm,40km

SC60=SCÌÖÂÛ,µ¥Ä£,1310nm,60km

SC80=SCÌÖÂÛ,µ¥Ä£,1550nm,80km

NA£ºÎÞ°ÙÕ×¹â¿Úʱ, ConnectorÏîΪ¿Õ

PS1-PS2:ÈßÓàµçÔ´ÊäÈë

L2-L2=24-48VDC(18-72VDC),ÈßÓàÊäÈë

L5-L5=12-24VDC(9-36VDC),ÈßÓàÊäÈë

 

 

 

Ñ¡¹ºÅä¼þ

Åä¼þÐͺÅ

Åä¼þ˵Ã÷

ǧÕ×SFPÄ £¿é

²Î¿¼¹¤Òµ¼¶Ç§Õ×SFPÄ £¿éÑ¡¹º±í

DT-BGAZ-02

±Ú¹Ò×°Öðå

DT-FCZ-RJ45-01

µ¥¿ÚRJ45·À³¾ÕÖ

DT-XL- Mini USB-USB-2m

USB¹ÜÀíÏßÀÂ,Mini USB to USB,2m

×ÊÁÏÏÂÔØ
ÍøÕ¾µØͼ