SICOM3216Íø¹ÜÐͽ»Á÷»úÊÇÒ»¿îÂÌÉ«¹¤ÒµÒÔÌ«Íø²úÆ·£¬×î¶àÖ§³Ö2¸öǧÕ×Combo½Ó¿Ú£¬2¸ö¹âµç¿ÉÑ¡°ÙÕ×½Ó¿ÚºÍ14¸ö°ÙÕ×µç¿Ú¡£SICOM3216Ö§³ÖDT-RingÐÒé×å(×ÔÓúʱ¼ä<50ms)£¬DRP/DHP£¨×ÔÓúʱ¼ä<20ms£©£¬RSTP£¬VLAN£¬×é²¥£¬QoS¡¢SSH, SSLµÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷£¬²¢Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ¡£SICOM3216¾ßÓÐIP40·À»¤µÄ½ðÊôÍâ¿Ç£¬¿¹Ç¿Õñ¶¯µÄ¿¨¹ì×ù£¬-40¡æ-+85¡æ¼«¶ËÇéÐÎζÈ˳ӦÄÜÁ¦¼°ÓÅÒìµÄEMCµç´Å¼æÈÝÐÔÄÜ£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦£¬ÏÖÔÚÒÑÆÕ±éÓ¦ÓÃÓÚ·çµç£¬ÅäÍø£¬½»Í¨£¬Ê¯ÓÍʯ»¯µÈ¹¤ÒµÁìÓò¡£
Èí¼þ¹¦Ð§ | |
½»Á÷¹¦Ð§ | Ö§³ÖVLAN, PVLAN Ö§³ÖGVRP Ö§³Ö¶Ë¿Ú¾ÛºÏ Ö§³Ö¶Ë¿ÚÁ÷¿Ø Ö§³Ö¶Ë¿ÚÏÞËÙ Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ |
ÈßÓàÊÖÒÕ | Ö§³ÖDT-Ring, DT-Ring+, DT-VLANÐÒé×å, ×ÔÓúʱ¼ä<50ms Ö§³ÖDRP/DHP,×ÔÓúʱ¼ä<20ms Ö§³ÖSTP/RSTP |
×é²¥ÊÖÒÕ | Ö§³ÖIGMP Snooping Ö§³ÖGMRP Ö§³Ö¾²Ì¬×é²¥ |
Çå¾²ÊÖÒÕ | Ö§³ÖHTTPs/SSL Ö§³ÖSSH Ö§³ÖTACACS+ Ö§³ÖIEEE802.1X Ö§³Ö¶Ë¿ÚMACµØÖ·°ó¶¨ |
·þÎñÖÊÁ¿¹ÜÀí | Ö§³ÖSP, WRRÐÐÁе÷Àí |
¹ÜÀíÓëά»¤ | Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨ Ö§³ÖSNMPv1/v2c/v3,¿Éͨ¹ýKyvision¼¯ÖйÜÀí Ö§³ÖFTP/TFTPÈí¼þÉý¼¶ Ö§³ÖµçÔ´¸æ¾¯,¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯ Ö§³Ö»·Â·¼ì²â Ö§³ÖCRC±£»¤ Ö§³ÖRMON Ö§³Ö¶Ë¿Ú¾µÏñ Ö§³ÖÏßÀ¹ÊÕϼì²â Ö§³ÖSyslog Ö§³ÖLLDP Ö§³ÖLink-check |
IP¹ÜÀí | Ö§³ÖDHCP server/snooping/client£¬DHCP Option 82 |
ʱÖÓ¹ÜÀí | Ö§³ÖSNTP Client |
²úÆ·¹æ¸ñ | |
±ê×¼ | IEEE 802.3i(10Base-T) IEEE 802.3u(100Base-TXºÍ100Base-FX) IEEE 802.3ab(1000Base-T) IEEE 802.3z(1000Base-SX/LX) IEEE 802.3x(Á÷¿Ø) IEEE 802.1p(ÓÅÏȼ¶) IEEE 802.1Q(VLAN) IEEE 802.1w(RSTP) IEEE802.1X |
½»Á÷ÊôÐÔ | ÓÅÏȼ¶ÐÐÁÐ 4 VLANÊý 256 VLAN ID 1¡«4093 ×é²¥×éÊý 256 MAC±í 8K °ü»º³åÇø 2Mbit °üת·¢ÂÊ 5.4Mpps ½»Á÷ÑÓ³Ù <5¦Ìs |
½Ó¿Ú | ǧÕ×¶Ë¿Ú 1000Base-X, SFP½Ó¿Ú; 10/100/1000Base-T(X), RJ45½Ó¿Ú °ÙÕ×¶Ë¿Ú 100Base-FX, µ¥/¶àÄ£SC/ST/FCÈÎÑ¡; 10/100Base-T(X), RJ45½Ó¿Ú Console¿Ú Mini USB½Ó¿Ú ¸æ¾¯¶Ë¿Ú 3о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max,2A Max |
ָʾµÆ | Ç°Ãæ°åָʾµÆ ÔËÐÐָʾµÆ:Run ¸æ¾¯Ö¸Ê¾µÆ:Alarm µçԴָʾµÆ:PWR1,PWR2 »·Ö¸Ê¾µÆ:Ring ½Ó¿ÚָʾµÆ:Link/ACT,Speed(µç¿Ú);Link/ACT(¹â¿Ú) |
°´Å¥ | Reset:Ö§³ÖÖØÆôºÍ»Ö¸´Ä¬ÈÏÉèÖà |
µçÔ´ | ÊäÈëµçѹ 24-48VDC(18-72VDC); 12-24VDC(9-36VDC) ½ÓÈë¶Ë×Ó 5о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó ¹¦ÂÊ <18W ¹ýÔر£»¤ Ö§³Ö ·´½Ó±£»¤ Ö§³Ö ÈßÓà±£»¤ Ö§³Ö |
»úе½á¹¹ | Íâ¿Ç ½ðÊô²ÄÖÊ É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ ·À»¤Æ·¼¶ IP40 ³ß´ç 88mm¡Á135mm¡Á137mm(W¡ÁH¡ÁD) ÖØÁ¿ 1.25Kg ×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ |
ÇéÐÎ | ÊÂÇéÎÂ¶È -40¡æ¡«+85¡æ Öü´æÎÂ¶È -40¡æ¡«+85¡æ Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶ |
Öʱ£ | MTBF 465000h ±£ÐÞÆÚ 5Äê |
ÈÏÖ¤ | UL508, Class I Div 2, CE(EMC), FCC: ½ÓÄÉL2:24-48VDCµçÔ´µÄÐͺÅ. UL508, Class I Div 2: ½ÓÄÉL5:12-24VDCµçÔ´µÄÐͺÅ. |
ÐÐÒµ±ê×¼ | EMI FCC CFR47 Part 15,EN55022/CISPR22,Class A EMS IEC61000-4-2(ESD) ¡À8kV(contact),¡À15kV(air) IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz) IEC61000-4-4(EFT) Power Port:¡À4kV;Data Port:¡À2kV IEC61000-4-5(Surge) Power Port: ¡À2kV/DM, ¡À4kV/CM; Data Port: ¡À2kV IEC61000-4-6(CS) 10V(150kHz¡«80MHz) »úе IEC60068-2-6(Õñ¶¯) IEC60068-2-27(¹¥»÷) IEC60068-2-32(×ÔÓɵøÂä) |
²úÆ·Ñ¡ÐÍ
ÍƼöÐͺÅ
²úÆ·ÐͺŠ|
SICOM3216-Ports-Connector-PS1-PS2 |
´úÂë½ç˵ |
´úÂëÑ¡ÐÍ |
Ports:¶Ë¿Ú |
16T=16×10/100Base-T(X) RJ45µç¿Ú 2S14T=2×100Base-FX,µ¥Ä£¹â¿Ú;14×10/100Base-T(X) RJ45µç¿Ú 2M14T=2×100Base-FX,¶àÄ£¹â¿Ú;14×10/100Base-T(X) RJ45µç¿Ú 2G16T=2×1000Base-X,10/100/1000Base-T(X) Combo½Ó¿Ú;16×10/100Base-T(X) RJ45µç¿Ú 2G2S14T=2×1000Base-X,10/100/1000Base-T(X) Combo½Ó¿Ú;2×100Base-FX,µ¥Ä£¹â¿Ú;14×10/100Base-T(X) RJ45µç¿Ú 2G2M14T=2×1000Base-X,10/100/1000Base-T(X) Combo½Ó¿Ú;2×100Base-FX,¶àÄ£¹â¿Ú;14×10/100Base-T(X) RJ45µç¿Ú |
Connector:°ÙÕ×¹â¿Ú²ÎÊý |
SC05=SCÌÖÂÛ,¶àÄ£,1310nm,5km ST05=STÌÖÂÛ,¶àÄ£,1310nm,5km FC05=FCÌÖÂÛ,¶àÄ£,1310nm,5km SC40=SCÌÖÂÛ,µ¥Ä£,1310nm,40km ST40=STÌÖÂÛ,µ¥Ä£,1310nm,40km FC40=FCÌÖÂÛ,µ¥Ä£,1310nm,40km SC60=SCÌÖÂÛ,µ¥Ä£,1310nm,60km SC80=SCÌÖÂÛ,µ¥Ä£,1550nm,80km NA£ºÎÞ°ÙÕ×¹â¿Úʱ, ConnectorÏîΪ¿Õ |
PS1-PS2:ÈßÓàµçÔ´ÊäÈë |
L2-L2=24-48VDC(18-72VDC),ÈßÓàÊäÈë L5-L5=12-24VDC(9-36VDC),ÈßÓàÊäÈë |
Ñ¡¹ºÅä¼þ
Åä¼þÐͺŠ|
Åä¼þ˵Ã÷ |
ǧÕ×SFPÄ£¿é |
²Î¿¼¹¤Òµ¼¶Ç§Õ×SFPÄ£¿éÑ¡¹º±í |
DT-BGAZ-02 |
±Ú¹Ò×°Öðå |
DT-FCZ-RJ45-01 |
µ¥¿ÚRJ45·À³¾ÕÖ |
DT-XL-Mini USB -USB-2m |
USB¹ÜÀíÏßÀÂ,Mini USB to USB,2m |