SICOM3024GSÊÇÕë¹ØÓÚÊÓƵ¼à¿Ø¡¢°²·ÀµÈϵͳ¶Ô´ó¹¦ÂÊPoE½»Á÷»úµÄÐèÇó¶øÉè¼Æ¿ª·¢µÄ¶þ²ã/Èý²ã¹ÜÀíÐ͹¤ÒµÒÔÌ«ÍøPoE½»Á÷»ú£¬Îª19Ó¢´ç1U»ú¼ÜʽװÖã¬×î¶àÖ§³Ö4¸öÍòÕ×»òÕßǧÕ×ÉÏÐж˿ںÍ24¸öǧÕ×PoE¶Ë¿Ú¡£SICOM3024GSµÄPoE¹¦Ð§Ö§³ÖIEEE802.3af/at±ê×¼£¬×î´ó¿É´ï240WµÄPoE¹¦ÂÊÊä³ö¡£Ö§³ÖVlan¡¢¿ìËÙÈßÓà»·Íø¡¢QosµÈ¸»ºñ¶þ²ãÌØÕ÷£¬Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPFµÈÈý²ã¹¦Ð§£¬¾ßÓиßÐÔÄÜÊÓƵ´«ÊäÄÜÁ¦£¬Ö§³Ö×é²¥ÐÒ飬²¢Ö§³Ö¸ßÐÔÄܵÄEMCÌØÕ÷£¬ÊÇÊÊÓÃÓÚÑÏ¿áµÄ¹¤ÒµÇéÐεÄÍø¹ÜÐÍ»ú¼Üʽ½»Á÷»ú¡£SICOM3024GS¾ßÓиߴø¿í¡¢¶à¶Ë¿Ú¡¢´ó¹¦ÂÊPoE¡¢¸ßÐÔÄÜÊÓƵ´«ÊäÄÜÁ¦µÈÌص㣬¿ÉÆÕ±éÓ¦ÓÃÓÚʯ»¯ÐÐÒµ¡¢¹ìµÀ½»Í¨ÐÐÒµ¡¢×Ô¶¯»¯¡¢µçÁ¦µÈ¸÷¸öÐÐÒµ¡£
Èí¼þ¹¦Ð§ | |
½»Á÷¹¦Ð§ | Ö§³ÖVLAN,PVLAN Ö§³ÖGVRP Ö§³Ö¶Ë¿Ú¾ÛºÏ, LACP Ö§³Ö¶Ë¿ÚÁ÷¿Ø Ö§³Ö»ùÓÚÁ÷µÄÏÞËÙ(ACLÏÞËÙÉèÖÃ) Ö§³ÖÈ«¾Ö¹ã²¥·ç±©ÒÖÖÆ(QOS·ç±©Õ½ÂÔ) |
ÈßÓàÊÖÒÕ | Ö§³ÖDT-ring, DT-ring+, DT-VLANÐÒé×壬×ÔÓúʱ¼ä<50ms Ö§³ÖDRP/DHP, ×ÔÓúʱ¼ä<20ms£¬ÇÒÓëÍøÂç¹æÄ£¾ÞϸÎÞ¹Ø Ö§³ÖRSTP/MSTP |
×é²¥ÊÖÒÕ | Ö§³ÖIGMP-snooping Ö§³ÖGMRP Ö§³Ö¾²Ì¬×é²¥ Ö§³ÖIGMP v2/v3 |
·ÓÉÊÖÒÕ£¨½öÈý²ãÖ§³Ö£© | Ö§³ÖOSFPv2 Ö§³Ö¾²Ì¬Â·ÓÉ Ö§³ÖRIPv1/v2 Ö§³ÖIGMP Ö§³ÖPIM-SM, PIM-DM |
Çå¾²ÊÖÒÕ | Ö§³ÖIEEE 802.1x Ö§³ÖHTTPs/SSL, SFTP Client Ö§³ÖSSH Ö§³ÖRADIUS Ö§³ÖTACACS+ Ö§³ÖÓû§·Ö¼¶ |
·þÎñÖÊÁ¿¹ÜÀí | Ö§³ÖACL Ö§³ÖQos, 802.1p£¨CoS£©ºÍDSCP Ö§³ÖSP,WRRÐÐÁе÷Àí |
¹ÜÀíÓëά»¤ | Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨ Ö§³ÖSNMPv1/v2c/v3£¬¿Éͨ¹ýKyvision¼¯ÖйÜÀí Ö§³ÖSFTP/HTTPÈí¼þÉý¼¶ Ö§³ÖµçÔ´¸æ¾¯, IP/MAC³åÍ»¸æ¾¯, ÄÚ´æ/CPUʹÓÃÂʸ澯, ¶Ë¿Ú¸æ¾¯, »·¸æ¾¯, ¶Ë¿ÚÁ÷Á¿¸æ¾¯, CRC¼°¶ª°üÂʸ澯, SFP½Ó¿ÚÎüÊչ⹦Âʸ澯ºÍ·¢Ë͹⹦Âʸ澯 Ö§³ÖDDM (SFP½Ó¿Ú) Ö§³Ö»·Â·¼ì²â Ö§³ÖRMON Ö§³Ö¶Ë¿Ú¾µÏñ Ö§³ÖSyslog Ö§³ÖLLDP Ö§³ÖLink-check |
IP¹ÜÀí | Ö§³ÖIPv4 Ö§³ÖIPv6 Ö§³ÖDHCP server/option12 Ö§³ÖPort Security over DHCP Ö§³ÖDHCP-relay-agent/option 82/61 Ö§³ÖDHCP Relay Agent Information Option Ö§³ÖDHCP Client Ö§³ÖDNS Ö§³ÖARP Ö§³Ö»ùÓÚNATµÄIPת»» |
ʱÖÓ¹ÜÀí | Ö§³ÖSNTP client Ö§³ÖNTP client Ö§³ÖPTPv2£¬¶Ôʱ¾«¶È¡À100ns |
²úÆ·¹æ¸ñ | |
ÊÖÒÕ±ê×¼ | IEEE 802.3i (10Base-T) IEEE 802.3u (100Base-T and 100Base-FX) IEEE 802.3z (1000Base-SX/LX) IEEE 802.3ad (Á´Â·¾ÛºÏ) IEEE 802.3x (Á÷¿Ø) IEEE 802.1p (ÓÅÏȼ¶) IEEE 802.1Q (VLAN) IEEE 802.1d (STP) IEEE 802.1w (RSTP) IEEE 802.1s (MSTP) IEEE 802.1x (Network Access Control) IEEE 802.1ab (LLDP) IEEE 802.3af IEEE 802.3at |
½»Á÷ÊôÐÔ | ÓÅÏȼ¶ÐÐÁÐ 8 VLANÊý 4K VLAN ID 1-4093 ×é²¥×éÊý 256 MAC±í 16K °ü»º³åÇø 32Mbit °üת·¢ÂÊ 83.3Mpps ½»Á÷ÑÓ³Ù £¼10us ÊÓƵ´«ÊäÄÜÁ¦£º Ö§³Ö24·ÉãÏñÍ·£¬ÎÞ¿¨¶Ù£» 4M/8M/12MÂëÁ÷£» Ö§³ÖJumboÖ¡¡£ |
½Ó¿Ú | ǧÕ×µç¿Ú 10/100/1000Base-T(X)×Ô˳ӦÒÔÌ«ÍøRJ45½Ó¿Ú ǧÕ×¹â¿Ú 1000Base-XǧÕ×SFP½Ó¿Ú ÍòÕ×¿Ú 10GBase-X, SFP+½Ó¿Ú Console¿Ú RS232, RJ45½Ó¿Ú ¸æ¾¯¶Ë×Ó 3о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max,2A Max,10A@1s, 60W Max USBÖü´æ Ò»ÆðUSB½Ó¿Ú£¬Ö§³Ö×Ô¶¯±¸·ÝÉèÖù¦Ð§ |
״ָ̬ʾµÆ | ÔËÐÐָʾµÆ:Run ¸æ¾¯Ö¸Ê¾µÆ:Alarm µçԴָʾµÆ:PWR1,PWR2 ½Ó¿ÚָʾµÆ:Link/ACT POEָʾµÆ:ACT |
µçÔ´ | ÊäÈëµçѹ 220VAC ½ÓÈë¶Ë×Ó 5о7.62mm¼ä¾à²åÈëʽ¶Ë×Ó ¹¦ÂÊ 240W PoE ¹¦ÂÊÊä³ö ¹ýÔر£»¤ Ö§³Ö ·´½Ó±£»¤ Ö§³Ö ÈßÓà±£»¤ Ö§³Ö |
»úе½á¹¹ | Íâ¿Ç ½ðÊô²ÄÖÊ É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´£¬ÎÞµçÉÈ ·À»¤Æ·¼¶ IP40 ³ß´ç 482.6mm¡Á44mm¡Á355.9mm(W¡ÁH¡ÁD) ÖØÁ¿ £¼5kg ×°Ö÷½·¨ 19Ó¢´ç1U»ú¼Üʽ |
ÇéÐÎ | ÊÂÇéÎÂ¶È -40¡æ¡«+75¡æ Öü´æÎÂ¶È -40¡æ¡«+85¡æ Ïà¶Ôʪ¶È 5-95%ÎÞÄý¶ |
Öʱ£ | MTBF £¾300000h ±£ÐÞÆÚ 5Äê |
ÐÐÒµ±ê×¼ | EMI FCC CFR47 Part 15,EN55022/CISPR22,Class A EMS IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air) IEC61000-4-3(RS) 80MHz-1000MHz£º10V/m and 20V/m£¬1.4GHz-2.1GHz£º10V/m£¬2.1GHz-2.5GHz£º5V/m IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À2kV IEC61000-4-5(Surge) Power Line to line 1KV£»Line to earth 2KV IEC61000-4-6(CS) 10V(150kHz-80MHz) IEC61000-4-8£¨¹¤Æµ´Å³¡£©300A/m(16.7Hz,50Hz,0Hz) IEC61000-4-9(Âö³å´Å³¡) 300A/m »úе IEC60068-2-6(Õñ¶¯) IEC60068-2-27(¹¥»÷) IEC60068-2-32(×ÔÓɵøÂä) |
²úÆ·Ñ¡ÐÍ
¶þ²ã½»Á÷»ú
²úÆ·ÐͺŠ| Êä³ö½Ó¿Ú | µçÔ´ |
SICOM3024GS-4X24GP-H3-H3 |
4×10GBase-X SFP+½Ó¿Ú£¬24×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-4GX24GP-H3-H3 |
4×1000Base-X SFP½Ó¿Ú£¬24×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-4X8GX16GP-H3-H3 |
4×10GBase-X SFP+½Ó¿Ú£¬8×1000Base-X SFP½Ó¿Ú£¬16×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-12GX16GP-H3-H3 |
12×1000Base-X SFP½Ó¿Ú£¬16×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-4X12GX12GP-H3-H3 |
4×10GBase-X SFP+½Ó¿Ú£¬12×1000Base-X SFP½Ó¿Ú£¬12×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-16GX12GP-H3-H3 |
16×1000Base-X SFP½Ó¿Ú£¬12×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
Èý²ã½»Á÷»ú
²úÆ·ÐͺŠ| Êä³ö½Ó¿Ú | µçÔ´ |
SICOM3024GS-L3G-4X24GP-H3-H3 |
4×10GBase-X SFP+½Ó¿Ú£¬24×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-L3G-4GX24GP-H3-H3 |
4×1000Base-X SFP½Ó¿Ú£¬24×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-L3G-4X8GX16GP-H3-H3 |
4×10GBase-X SFP+½Ó¿Ú£¬8×1000Base-X SFP½Ó¿Ú£¬16×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-L3G-12GX16GP-H3-H3 |
12×1000Base-X SFP½Ó¿Ú£¬16×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-L3G-4X12GX12GP-H3-H3 |
4×10GBase-X SFP+½Ó¿Ú£¬12×1000Base-X SFP½Ó¿Ú£¬12×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
SICOM3024GS-L3G-16GX12GP-H3-H3 |
16×1000Base-X SFP½Ó¿Ú£¬12×10/100/1000Base-T(X) RJ45 PoEµç¿Ú |
220VAC(85-264VAC)£¬ÈßÓàÊäÈë |
Ñ¡¹ºÅä¼þ
Åä¼þ | Åä¼þ˵Ã÷ |
ÍòÕ×SFP+Ä£¿é | ²Î¿¼¹¤Òµ¼¶ÍòÕ×SFP+Ä£¿éÑ¡¹º±í |
ǧÕ×SFPÄ£¿é | ²Î¿¼¹¤Òµ¼¶Ç§Õ×SFPÄ£¿éÑ¡¹º±í |
RJ45·À³¾ÕÖ | µ¥¿ÚRJ45·À³¾ÕÖ£¬ÐͺţºDT-FCZ-RJ45-01 |
´®¿ÚÏß | RJ45/DB9£¬2Ã×£¬±àÂ룺111030019 |
µçÔ´Ïß | 3ÏàµçÔ´Ïߣ¬3Ã×£¬±àÂ룺111020004 |
µçÔ´¶Ë×Ó | 5о7.62ºÁÃ×¼ä¾àµçÔ´¶Ë×Ó£¬±àÂ룺107010125 |
¸æ¾¯¶Ë×Ó | 3о5.08ºÁÃ×¼ä¾à¸æ¾¯¶Ë×Ó£¬±àÂ룺107010124 |
¹Ò¶ú | µ¥¸ö×°ÖùҶú£¬±àÂ룺109999003 |