×ðÁú¿­Ê±

²úƷͼƬ²úÆ·¼ò½éÒªº¦ÌØÕ÷ÐÔÄܲÎÊý»úе³ß´ç¶©¹ºÐÅÏ¢×ÊÁÏÏÂÔØ
·¢ËÍѯÅÌ
SICOM3016B
16+4G¶Ë¿Ú¶þ²ãÍø¹ÜÐÍ¿¨¹ìʽ½»Á÷»ú
²úÆ·¼ò½é

SICOM3016BϵÁÐÍø¹ÜÐͽ»Á÷»úÊÇרΪ¹¤ÒµÓ¦ÓÃÁìÓòÉè¼ÆµÄ¸ßÃܶȶ˿ڲúÆ· £¬×î¶àÖ§³Ö4¸öǧÕ×Combo½Ó¿ÚºÍ16¸ö°ÙÕ×µç¿Ú ¡£Æä½áʵµÄ½ðÊôÍâ¿Ç £¬ÀßÐÔÉ¢ÈÈÉè¼Æ £¬µçÔ´²àµÄ¹ýÁ÷ £¬¹ýѹ £¬EMC·À»¤Éè¼Æ £¬ÐźſڵÄEMC·À»¤Éè¼ÆµÈ¹¤ÒµÌØÕ÷ £¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦ ¡£SICOM3016BÖ§³ÖDT-RingЭÒé×å(×ÔÓúʱ¼ä<50ms) £¬ RSTP £¬VLAN £¬×é²¥ £¬QoSµÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷ £¬²¢Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2cµÄÍø¹ÜÈí¼þ ¡£

Òªº¦ÌØÕ÷

 

ÐÔÄܲÎÊý
Èí¼þ¹¦Ð§
½»Á÷¹¦Ð§ Ö§³ÖVLAN, PVLAN
Ö§³Ö¶Ë¿Ú¾ÛºÏ
Ö§³Ö¶Ë¿ÚÁ÷¿Ø
Ö§³Ö¶Ë¿ÚÏÞËÙ
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
ÈßÓàÊÖÒÕ Ö§³ÖDT-Ring, DT-Ring+, DT-VLANЭÒé×å, ×ÔÓúʱ¼ä<50ms
Ö§³ÖDRP,×ÔÓúʱ¼ä<20ms
Ö§³ÖSTP/RSTP
×é²¥ÊÖÒÕ Ö§³ÖIGMP Snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
Çå¾²ÊÖÒÕ Ö§³Ö¶Ë¿Ú¸ôÀë
·þÎñÖÊÁ¿¹ÜÀí Ö§³ÖSP, WRRÐÐÁе÷Àí
Ö§³ÖACL
¹ÜÀíÓëά»¤ Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨
Ö§³ÖSNMPv1/v2c, ¿Éͨ¹ýKyvision¼¯ÖйÜÀí
Ö§³ÖFTPÈí¼þÉý¼¶
Ö§³ÖIP/MAC³åÍ»¸æ¾¯,µçÔ´¸æ¾¯,¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯
Ö§³Ö»·Â·¼ì²â
Ö§³ÖCRC±£»¤
Ö§³ÖRMON
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖSyslog
Ö§³ÖLLDP
Ö§³ÖLink-check
IP¹ÜÀí Ö§³ÖDHCP Server/Client
ʱÖÓ¹ÜÀí Ö§³ÖSNTP Server/Client
²úÆ·¹æ¸ñ
±ê×¼ IEEE 802.3i (10Base-T)
IEEE 802.3u (100Base-T)
IEEE 802.3ab(1000Base-T)
IEEE 802.3z (1000Base-SX/LX)
IEEE802.3x (Á÷¿Ø)
IEEE 802.1p (ÓÅÏȼ¶)
IEEE 802.1Q (VLAN)
IEEE 802.1D(STP)
IEEE 802.1w (RSTP)
½»Á÷ÊôÐÔ ÓÅÏȼ¶ÐÐÁÐ 4
VLANÊý 256
VLAN ID 1¡«4093
×é²¥×éÊý 256
MAC±í 8K
°ü»º³åÇø 4Mbit
°üת·¢ÂÊ 8.3Mpps
½»Á÷ÑÓ³Ù <10¦Ìs
½Ó¿Ú ǧÕ×¶Ë¿Ú 1000Base-X, SFP½Ó¿Ú; 10/100/1000Base-T(X), RJ45½Ó¿Ú
°ÙÕ×¶Ë¿Ú 10/100Base-T(X), RJ45½Ó¿Ú
Console¿Ú RS232,RJ45½Ó¿Ú
¸æ¾¯¶Ë¿Ú 3о3.81mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max, 2A Max
ָʾµÆ Ç°Ãæ°åָʾµÆ
ÔËÐÐָʾµÆ:Run
¸æ¾¯Ö¸Ê¾µÆ:Alarm
µçԴָʾµÆ:PWR1,PWR2
½Ó¿ÚָʾµÆ:Link/ACT,Speed(µç¿Ú), Link/ACT(¹â¿Ú)
µçÔ´ ÊäÈëµçѹ 100-240VAC,50/60Hz;220VDC(85-264VAC/120-300VDC); 48VDC(36-72VDC); 24VDC(18-36VDC)
½ÓÈë¶Ë×Ó 5о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó
¹¦ÂÊ <14W
¹ýÔر£»¤ Ö§³Ö
·´½Ó±£»¤ Ö§³Ö
ÈßÓà±£»¤ Ö§³Ö(24/48VDC)
»úе½á¹¹ Íâ¿Ç ½ðÊô²ÄÖÊ
É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ
·À»¤Æ·¼¶ IP40
³ß´ç 75mm¡Á165mm¡Á123mm(W¡ÁH¡ÁD)
ÖØÁ¿ 1.2Kg
×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ
ÇéÐÎ ÊÂÇéÎÂ¶È -40¡æ¡«+85¡æ
Öü´æÎÂ¶È -40¡æ¡«+85¡æ
Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶
Öʱ£ MTBF 334038h
±£ÐÞÆÚ 5Äê
ÈÏÖ¤ ÈÏÖ¤ CE(EMC), FCC: ½ÓÄÉL3:24VDCµçÔ´µÄÐͺÅ.
ÐÐÒµ±ê×¼ EMI
FCC CFR47 Part 15,EN55022/CISPR22,Class A

EMS
IEC61000-4-2(ESD) ¡À8kV(contact),¡À15kV(air)
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
IEC61000-4-4(EFT) Power Port:¡À4kV;Data Port:¡À2kV
IEC61000-4-5(Surge) Power Port:¡À2kV/DM,¡À4kV/CM;Data Port:¡À2kV
IEC61000-4-6(CS) 10V(150kHz¡«80MHz)

»úе
IEC60068-2-6(Õñ¶¯)
IEC60068-2-27(¹¥»÷)
IEC60068-2-32(×ÔÓɵøÂä)
»úе³ß´ç

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

ÍƼöÐͺÅ

²úÆ·ÐͺÅ

SICOM3016B-Ports-PS1-PS2

SICOM3016B-Ports-PS1

´úÂë½ç˵

´úÂëÑ¡ÐÍ

Ports:¶Ë¿Ú

4G16T=4×1000Base-X,10/100/1000Base-T(X) Combo½Ó¿Ú; 16×10/100Base-T(X) RJ45µç¿Ú

2G2GE16T=2×1000Base-X, 10/100/1000Base-T(X) Combo½Ó¿Ú; 2×10/100/1000Base-T(X) RJ45µç¿Ú; 16×10/100Base-T(X) RJ45µç¿Ú

PS1-PS2:ÈßÓàµçÔ´ÊäÈë

L1-L1=48VDC(36-72VDC),ÈßÓàÊäÈë

L3-L3=24VDC(18-36VDC),ÈßÓàÊäÈë

PS1:µ¥µçÔ´ÊäÈë

H1=100-240VAC,50/60Hz;220VDC(85-264VAC/120-300VDC),µ¥Â·ÊäÈë

 

 

Ñ¡¹ºÅä¼þ

Åä¼þÐͺÅ

Åä¼þ˵Ã÷

ǧÕ×SFPÄ£¿é

²Î¿¼¹¤Òµ¼¶Ç§Õ×SFPÄ£¿éÑ¡¹º±í

DT-BGAZ-05

±Ú¹Ò×°Öðå

DT-FCZ-RJ45-01

µ¥¿ÚRJ45·À³¾ÕÖ

×ÊÁÏÏÂÔØ
ÍøÕ¾µØͼ