SICOM3005AÊÇÒ»¿î¿¨¹ìʽ¼¯ÒÔÌ«Íø¡¢´®ÐÐÊý¾Ýת·¢ÓÚÒ»ÌåµÄ´®¿Ú·þÎñÆ÷£¬¿ÉʵÏÖRS232/485/422ÐÒéÓëÒÔÌ«ÍøÐÒéµÄÖ±½Óת»»£¬Ö§³Ö¸»ºñµÄ´®¿Ú¹ÜÀíºÍ½»Á÷ÐÒé¡£Ö÷ÒªÓ¦ÓÃÔÚ·çµç¡¢ÅäÍø×Ô¶¯»¯¡¢µçÁ¦¡¢ÖÇÄܽ»Í¨µÈÁìÓòµÄ½ÓÈë²ã¡£
Èí¼þÌØÕ÷ | |
´®¿Ú¹¦Ð§ | ÌṩAPI½Ó¿Ú£¬Ö§³Ö»ùÓÚLinuxƽ̨µÄ¶þ´Î¿ª·¢ Ö§³ÖRS232/484/422ÓëÒÔÌ«ÍøÐÒéµÄת»» Ö§³Ö´®¿ÚÈí¼þÁ÷¿Ø ͨ¹ýTCP Client°×Ãûµ¥ÊµÏÖ´®¿ÚͨѶÇå¾²¹ÜÀí Ö§³Ö´®¿Ú¾µÏñ¡¢Vlan»®·Ö¡¢¾²Ì¬Â·ÓÉ Í¨Ñ¶Êý¾Ýͳ¼Æ |
½»Á÷¹¦Ð§ | Ö§³ÖVLAN,PVLAN Ö§³ÖGVRP Ö§³Ö¶Ë¿Ú¾ÛºÏ Ö§³Ö¶Ë¿ÚÁ÷¿Ø Ö§³Ö¶Ë¿ÚÏÞËÙ Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ Ö§³ÖARP |
ÈßÓàÊÖÒÕ | Ö§³ÖDT-Ring, DT-Ring+, DT-VLANÐÒé×壬×ÔÓúʱ¼ä<50ms Ö§³ÖDRP,DHP,»·Íø»Ö¸´Ê±¼ä<20ms Ö§³ÖSTP/RSTP |
×é²¥ÊÖÒÕ | Ö§³ÖIGMP Snooping Ö§³ÖGMRP Ö§³Ö¾²Ì¬×é²¥ |
Çå¾²ÊÖÒÕ | Ö§³ÖHTTPs/SSL Ö§³ÖSSH Ö§³ÖTACACS+ Ö§³ÖIEEE802.1X Ö§³Ö¶Ë¿ÚMACµØÖ·°ó¶¨ Ö§³Ö¶Ë¿ÚÇå¾² Ö§³ÖAAA |
·þÎñÖÊÁ¿¹ÜÀí | Ö§³ÖSP, WRRÐÐÁе÷Àí |
¹ÜÀíÓëά»¤ | Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨ Ö§³ÖSNMPv1/v2c/v3£¬¿Éͨ¹ýKyvision¼¯ÖйÜÀí Ö§³ÖFTP/TFTPÈí¼þÉý¼¶ Ö§³ÖµçÔ´¸æ¾¯£¬¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯ Ö§³Ö»·Â·¼ì²â Ö§³ÖCRC±£»¤ Ö§³ÖRMON Ö§³Ö¶Ë¿Ú¾µÏñ Ö§³ÖÏßÀ¼ì²â Ö§³ÖSyslog Ö§³ÖLLDP Ö§³ÖLink-check |
IP¹ÜÀí | Ö§³ÖDHCP server/snooping/client£¬DHCP Option 82 |
ʱÖÓ¹ÜÀí | Ö§³ÖSNTP Client |
²úÆ·¹æ¸ñ | |
±ê×¼ | RS232/485/422 IEEE 802.3i(10Base-T) IEEE 802.3u(100Base-TXºÍ100Base-FX) IEEE 802.3x(Á÷¿Ø) IEEE 802.1p(ÓÅÏȼ¶) IEEE 802.1Q(VLAN) IEEE 802.1D(STP) IEEE 802.1w(RSTP) |
½»Á÷ÊôÐÔ | ÓÅÏȼ¶ÐÐÁÐ 4 VLANÊý 256 VLAN ID 1¡«4093 ×é²¥×éÊý 256 MAC±í 8K °ü»º³åÇø 2Mbit °üת·¢ÂÊ 0.9Mpps ½»Á÷ÑÓ³Ù <5¦Ìs |
½Ó¿Ú | °ÙÕ×¶Ë¿Ú 100Base-FX,µ¥/¶àÄ£,SC/ST/FCÈÎÑ¡; 10/100Base-T(X),RJ45½Ó¿Ú ´®ÐÐ¿Ú RS232/RS485/RS422,RJ50½Ó¿Ú Console¿Ú RS232,RJ45½Ó¿Ú ¸æ¾¯¶Ë¿Ú 3о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max, 2A Max |
ָʾµÆ | Ç°Ãæ°åָʾµÆ ÔËÐÐָʾµÆ:Run1 ´®¿Ú·þÎñÆ÷ÔËÐÐָʾµÆ:Run2 ¸æ¾¯Ö¸Ê¾µÆ:Alarm (12/24/48VDCÊäÈëÐͺÅÖ§³Ö) µçԴָʾµÆ:PWR1,PWR2 »·Ö¸Ê¾µÆ:Ring ½Ó¿ÚָʾµÆ:Link/ACT,Speed(µç¿Ú);Link/ACT(¹â¿Ú) ´®¿ÚÊÕ·¢Ö¸Ê¾µÆ:·¢ËÍÊý¾Ý(ÂÌÉ«), ÎüÊÕÊý¾Ý(»ÆÉ«) |
°´Å¥ | ResetÖ§³Ö½»Á÷ϵͳÖØÆôºÍ»Ö¸´Ä¬ÈÏÉèÖà |
µçÔ´ | ÊäÈëµçѹ 100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC); 24-48VDC(18-72VDC); 12-24VDC(9-36VDC) ½ÓÈë¶Ë×Ó 5о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó ¹¦ÂÊ <10W ¹ýÔر£»¤ Ö§³Ö ·´½Ó±£»¤ Ö§³Ö ÈßÓà±£»¤ Ö§³Ö |
»úе½á¹¹ | Íâ¿Ç ½ðÊô²ÄÖÊ É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ ·À»¤Æ·¼¶ IP40 ³ß´ç 66mm¡Á135mm¡Á107.5mm(W¡ÁH¡ÁD) ÖØÁ¿ 0.6Kg ×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ |
ÇéÐÎ | ÊÂÇéÎÂ¶È -40¡æ¡«+75¡æ Öü´æÎÂ¶È -40¡æ¡«+85¡æ Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶ |
Öʱ£ | MTBF 307699h ±£ÐÞÆÚ 5Äê |
ÐÐÒµ±ê×¼ | EMI CFR47 Part 15,EN55022/CISPR22,Class A EMS IEC61000-4-2(ESD) ¡À8kV(contact),¡À15kV(air) IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz) IEC61000-4-4(EFT) Power Port:¡À4kV;Data Port:¡À2kV IEC61000-4-5(Surge) Power Port:¡À2kV/DM,¡À4kV/CM;Data Port:¡À2kV IEC61000-4-6(CS) 3V(10kHz¡«150kHz);10V(150kHz¡«80MHz) »úе IEC60068-2-6(Õñ¶¯) IEC60068-2-27(¹¥»÷) IEC60068-2-32(×ÔÓɵøÂä) |
²úÆ·Ñ¡ÐÍ
ÍƼöÐͺÅ
²úÆ·ÐͺŠ|
SICOM3005A-Ports-Connector-PS1-PS2 SICOM3005A-Ports-Connector-PS1 |
´úÂë½ç˵ |
´úÂëÑ¡ÐÍ |
Ports:¶Ë¿Ú |
2S4T4D=2×100Base-FX,µ¥Ä£¹â¿Ú;4×10/100Base-T(X) RJ45µç¿Ú;4¸öRS232/485/422´®¿Ú 2M4T4D=2×100Base-FX,¶àÄ£¹â¿Ú;4×10/100Base-T(X) RJ45µç¿Ú;4¸öRS232/485/422´®¿Ú 6T4D=6×10/100Base-T(X) RJ45µç¿Ú;4¸öRS232/485/422´®¿Ú 2S4T=2×100Base-FX,µ¥Ä£¹â¿Ú;4×10/100Base-T(X) RJ45µç¿Ú 2M4T=2×100Base-FX,¶àÄ£¹â¿Ú;4×10/100Base-T(X) RJ45µç¿Ú 6T=6×10/100Base-T(X) RJ45µç¿Ú |
Connector:°ÙÕ×¹â¿Ú²ÎÊý |
SC05=SCÌÖÂÛ,¶àÄ£,1310nm,5km ST05=STÌÖÂÛ,¶àÄ£,1310nm,5km FC05=FCÌÖÂÛ,¶àÄ£,1310nm,5km SC40=SCÌÖÂÛ,µ¥Ä£,1310nm,40km ST40=STÌÖÂÛ,µ¥Ä£,1310nm,40km FC40=FCÌÖÂÛ,µ¥Ä£,1310nm,40km SC60=SCÌÖÂÛ,µ¥Ä£,1310nm,60km SC80=SCÌÖÂÛ,µ¥Ä£,1550nm,80km NA£ºÎÞ°ÙÕ×¹â¿Úʱ, ConnectorÏîΪ¿Õ |
PS1-PS2:µçÔ´ÊäÈë |
L2-L2=24-48VDC(18-72VDC),ÈßÓàÊäÈë L5-L5=12-24VDC(9-36VDC),ÈßÓàÊäÈë |
PS1:µ¥µçÔ´ÊäÈë |
HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC),µ¥Â·ÊäÈë |
Ñ¡¹ºÅä¼þ
Åä¼þÐͺŠ|
Åä¼þ˵Ã÷ |
DT-BGAZ-09 |
±Ú¹Ò×°Öðå |
DT-FCZ-RJ45-01 |
µ¥¿ÚRJ45·À³¾ÕÖ |