×ðÁú¿­Ê±

²úƷͼƬ²úÆ·ÊÓƵ²úÆ·¼ò½éÒªº¦ÌØÕ÷ÐÔÄܲÎÊý»úе³ß´ç¶©¹ºÐÅÏ¢×ÊÁÏÏÂÔØ
·¢ËÍѯÅÌ
SICOM3000A-PN
¶þ²ãÍø¹ÜÐÍ¿¨¹ìʽÒÔÌ«Íø½»Á÷»ú
²úÆ·ÊÓƵ
²úÆ·¼ò½é

SICOM3000AϵÁÐÊǶþ²ã¿¨¹ìʽ¹ÜÀíÐ͹¤ÒµÒÔÌ«Íø½»Á÷»ú£¬Ìṩ¸»ºñµÄ²úÆ·¶Ë¿Ú×éºÏ£¬6/8/10/12/16/18/20¿Ú£¬100/1000M SFP½Ó¿Ú£¬12/24/48/110/220VµçѹÊäÈë¡£SICOM3000AÖ§³ÖDT-RingЭÒé×å(×ÔÓúʱ¼ä<50ms)£¬DRP/DHP/MRP£¨×ÔÓúʱ¼ä<20ms£©£¬STP/RSTP/MSTP£¬VLAN£¬×é²¥£¬QoS£¬SSHµÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷£¬²¢Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ¡£Ö§³ÖIEEE1588 PTPV2, ×Ô¶¯ÉèÖñ¸·ÝºÍ»Ö¸´£¬ DDM(SFP½Ó¿Ú)£¬Ö§³ÖPROFINET(-PNÐͺÅ)£¬Ethernet IPºÍModbus TCPЭÒé¡£SICOM3000A¾ßÓÐIP40·À»¤µÄ½ðÊôÍâ¿Ç£¬¿¹Ç¿Õñ¶¯µÄ¿¨¹ì×ù£¬¼«¶ËÇéÐÎζÈ˳ӦÄÜÁ¦¼°ÓÅÒìµÄEMCµç´Å¼æÈÝÐÔÄÜ£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦¡£²úÆ·¿ÉÆÕ±éÓ¦ÓÃÓÚ¹¤³§×Ô¶¯»¯£¬½»Í¨£¬Ê¯ÓÍʯ»¯£¬·çµç£¬ÅäÍøµÈ¹¤ÒµÁìÓò¡£

Òªº¦ÌØÕ÷

Ö§³Ö100Base-X, 1000Base-X SFP½Ó¿Ú
Ö§³ÖÈßÓàЭÒ飺DT-Ring(×ÔÓúʱ¼ä<50ms)£¬DRP/DHP/MRP£¨×ÔÓúʱ¼ä<20ms£©£¬STP/RSTP/MSTP
Ö§³ÖÇå¾²ÊÖÒÕ£ºHTTPS/SSL£¬SSH£¬TACACS+£¬IEEE802.1X£¬RADIUS£¬Óû§·Ö¼¶£¬¶Ë¿ÚMACµØÖ·°ó¶¨
Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ
Ö§³Ö×Ô¶¯ÉèÖñ¸·ÝºÍ»Ö¸´
Ö§³Ö»ùÓÚÓ²¼þµÄIEEE1588 PTPv2 (BC, P2P TC, E2E TCʱÖÓģʽ,¶Ôʱ¾«¶È ±100 ns)
Ö§³Ö PROFINET(-PNÐͺÅ)£¬Ethernet IPºÍModbus TCPЭÒé
Ö§³ÖDDM (SFP½Ó¿Ú)
IP40·À»¤Æ·¼¶

ÐÔÄܲÎÊý
Èí¼þ¹¦Ð§
½»Á÷¹¦Ð§ Ö§³ÖVLAN, PVLAN
Ö§³ÖGVRP
Ö§³Ö¶Ë¿Ú¾ÛºÏ, LACP
Ö§³Ö¶Ë¿ÚÁ÷¿Ø
Ö§³Ö»ùÓÚÁ÷µÄÏÞËÙ(ACLÏÞËÙÉèÖÃ)
Ö§³ÖÈ«¾Ö¹ã²¥·ç±©ÒÖÖÆ(QoS·ç±©Õ½ÂÔ)
ÈßÓàÊÖÒÕ Ö§³ÖDT-Ring, DT-Ring+, DT-VLANЭÒé×壬×ÔÓúʱ¼ä<50ms
Ö§³ÖDRP/DHP,×ÔÓúʱ¼ä<20ms
Ö§³ÖSTP/RSTP/MSTP/G.8032 ERPS
Ö§³ÖMRP£¬MRM&MRC
×é²¥ÊÖÒÕ Ö§³ÖIGMP Snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
Ö§³ÖIGMPv2/v3
Çå¾²ÊÖÒÕ Ö§³ÖHTTPS/SSL
Ö§³ÖSSH
Ö§³ÖTACACS+
Ö§³ÖIEEE802.1X
Ö§³ÖRADIUS
Ö§³ÖÓû§·Ö¼¶
Ö§³Ö¶Ë¿ÚMACµØÖ·°ó¶¨
·þÎñÖÊÁ¿¹ÜÀí Ö§³ÖQoS, 802.1p(CoS), DSCP
Ö§³ÖSP,WRRÐÐÁе÷Àí
Ö§³ÖACL
¹¤ÒµÐ­Òé Ö§³ÖPROFINET (PROFINETÒ»ÖÂÐÔÆ·¼¶B, PROFINET IOÕï¶Ï, GSDÎļþ, ͨ¹ýSTEP7¾ÙÐÐÉèÖúÍÕï¶Ï)
Ö§³ÖEtherNet/IP
Ö§³ÖModbus/TCP
¹ÜÀíÓëά»¤ Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨
Ö§³ÖSNMPv1/v2c/v3£¬¿Éͨ¹ýKyvision¼¯ÖйÜÀí
Ö§³ÖSFTP/HTTPÈí¼þÉý¼¶
Ö§³ÖµçÔ´¸æ¾¯, IP/MAC³åÍ»¸æ¾¯, ÄÚ´æ/CPUʹÓÃÂʸ澯, ¶Ë¿Ú¸æ¾¯, »·¸æ¾¯, ¶Ë¿ÚÁ÷Á¿¸æ¾¯, CRC¼°¶ª°üÂʸ澯, SFP½Ó¿ÚÎüÊչ⹦Âʸ澯ºÍ·¢Ë͹⹦Âʸ澯
Ö§³ÖDDM (SFP½Ó¿Ú)
Ö§³Ö»·Â·¼ì²â
Ö§³ÖRMON
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖSyslog
Ö§³ÖLLDP
Ö§³ÖLink-check
Ö§³Ö×Ô¶¯ÉèÖñ¸·ÝºÍ»Ö¸´
Ö§³ÖIPv4/IPv6
IP¹ÜÀí Ö§³ÖDHCP server/snooping/client, DHCP Option 82
Ö§³ÖARP
ʱÖÓ¹ÜÀí Ö§³ÖSNTP Client
Ö§³ÖPTP
²úÆ·¹æ¸ñ
ÊÖÒÕ²ÎÊý ±ê×¼
IEEE 802.3i (10Base-T)
IEEE 802.3u (100Base-T and 100Base-FX)
IEEE 802.3ab (1000Base-T)
IEEE 802.3z (1000Base-SX/LX)
IEEE 802.3ad (Á´Â·¾ÛºÏ)
IEEE 802.3x (Á÷¿Ø)
IEEE 802.1p (ÓÅÏȼ¶)
IEEE 802.1Q (VLAN)
IEEE 802.1d (STP)
IEEE 802.1w (RSTP)
IEEE 802.1s (MSTP)
IEEE 802.1x (Network Access Control)
IEEE 802.1ab (LLDP)
IEEE1588 V2 (PTP)
½»Á÷ÊôÐÔ ÓÅÏȼ¶ÐÐÁÐ 8
VLANÊý 4K
VLAN ID 1¡«4094
×é²¥×éÊý 8K
MAC±í 8K
°ü»º³åÇø 4Mbit
±³°å´ø¿í 40Gbps
°üת·¢ÂÊ
1.5Mpps (2SFP8T), 1.8Mpps (4SFP8T)
4.2Mpps (2GX8T), 10.2Mpps (4GX8T)
14.9Mpps (2GX8GE), 17.9Mpps (4GX8GE)
3.0Mpps (4SFP16T), 8.3Mpps (4GX16T)
2.4Mpps (8SFP8T), 13.1Mpps (8GX8T)
29.8Mpps (4GX16GE,12GX8GE), 23.8Mpps (8GX8GE)
½»Á÷ÑÓ³Ù <5¦Ìs
³¬³¤Ö¡³¤¶È 9.6KB
½Ó¿Ú ǧÕ׶˿Ú
100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú
10/100/1000Base-T(X), RJ45½Ó¿Ú

°ÙÕ׶˿Ú
100Base-X SFP½Ó¿Ú
10/100Base-T(X), RJ45½Ó¿Ú

Console¿Ú RS232,RJ45½Ó¿Ú
¸æ¾¯¶Ë¿Ú 3о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max, 2A Max
ָʾµÆ Ç°Ãæ°åָʾµÆ
ÔËÐÐָʾµÆ:Run
¸æ¾¯Ö¸Ê¾µÆ:Alarm
µçԴָʾµÆ:PWR1,PWR2
»·Ö¸Ê¾µÆ:Ring
½Ó¿ÚָʾµÆ:Link/ACT,Speed(µç¿Ú);Link/ACT(¹â¿Ú)
°´Å¥ Reset:Ö§³ÖÖØÆôºÍ»Ö¸´Ä¬ÈÏÉèÖÃ
µçÔ´ ÊäÈëµçѹ
100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC)
24-48VDC(18-72VDC)
12-24VDC(9-36VDC)

½ÓÈë¶Ë×Ó
5о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó (L2/L5)
3о7.62mm¼ä¾à²åÈëʽ¶Ë×Ó (HV)

¹¦ÂÊ
<11W (4GX8T)
<13W (4GX8GE)
<20W (4GX16GE,12GX8GE)

¹ýÔر£»¤ Ö§³Ö
·´½Ó±£»¤ Ö§³Ö
ÈßÓà±£»¤ Ö§³Ö (12/24/48VDC)
»úе½á¹¹ Íâ¿Ç ½ðÊô²ÄÖÊ
É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ
·À»¤Æ·¼¶ IP40¼°ÒÔÉÏ
³ß´ç
66mm¡Á135mm¡Á107.5mm (6T,8T,2GX8T,4GX8T) (W¡ÁH¡ÁD)
88mm¡Á135mm¡Á137mm (8GE,2GX8GE,4GX8GE) (W¡ÁH¡ÁD)
102mm¡Á135mm¡Á137mm (16GE,2GX16GE,4GX16GE,8GX8GE,12GX8GE) (W¡ÁH¡ÁD)

ÖØÁ¿
1.1Kg (6T,8T,2GX8T,4GX8T)
1.5Kg (8GE,2GX8GE,4GX8GE)
1.9Kg (16GE,2GX16GE,4GX16GE,8GX8GE,12GX8GE)

×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ
ÇéÐÎ ÊÂÇéÎÂ¶È -40¡æ¡«+85¡æ
Öü´æÎÂ¶È -40¡æ¡«+85¡æ
Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶
Öʱ£ MTBF
1681195h (6T)
1675852h (8T)
1657563h (4GX8T)
1317486h (4GX8GE)
1272643h (12GX8GE)
1097144h (4GX16GE)

±£ÐÞÆÚ 5Äê
ÈÏÖ¤ CE, FCC
EMC: EN 55032/35, EN 61000-6-4, EN 61000-6-2
Rail Traffic: EN 50121-4
UL61010, Class I Div 2, IECEx, ATEX Zone 2, Ex ec nC IIC T4 Gc
IEC61850-3, IEEE1613
PROFINET Conformance Class B
IEC 62368-1, EN 62368-1
ÐÐÒµ±ê×¼ EMI
FCC CFR47 Part 15,EN55032/CISPR22,Class A
EMS
IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air)
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À1kV
IEC61000-4-5(Surge) Power Port:¡À1kV/DM,¡À2kV/CM;Data Port:¡À1kV
IEC61000-4-6(CS) 10V(150kHz¡«80MHz)
»úе
IEC60068-2-6(Õñ¶¯)
IEC60068-2-27(¹¥»÷)
IEC60068-2-32(×ÔÓɵøÂä)
»úе³ß´ç

66mm×135mm×107.5mm(W×H×D):

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

88mm×135mm×137mm(W×H×D):

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

 

102mm×135mm×137mm(W×H×D):

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

¶©¹ºÐÅÏ¢

ÍƼöÐͺÅ

²úÆ·ÐͺÅ

SICOM3000A-Ports-PS1-PS2

SICOM3000A-Ports-PS1-PS2-PN

´úÂë½ç˵

´úÂëÑ¡ÐÍ

Ports

66mm×135mm×107.5mm(W×H×D):

6T=6×10/100Base-T(X) RJ45µç¿Ú

8T=8×10/100Base-T(X) RJ45µç¿Ú

2SFP8T=2×100Base-X SFP½Ó¿Ú; 8×10/100Base-T(X) RJ45µç¿Ú

2GX8T=2×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100Base-T(X) RJ45µç¿Ú

4SFP8T=4×100Base-X SFP½Ó¿Ú; 8×10/100Base-T(X) RJ45µç¿Ú

4GX8T=4×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100Base-T(X) RJ45µç¿Ú

 

88mm×135mm×137mm(W×H×D):

8GE=8×10/100/1000Base-T(X) RJ45µç¿Ú

2GX8GE=2×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100/1000Base-T(X) RJ45µç¿Ú

4GX8GE=4×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100/1000Base-T(X) RJ45µç¿Ú

 

102mm×135mm×137mm(W×H×D):

16T=16×10/100Base-T(X) RJ45µç¿Ú

16GE=16×10/100/1000Base-T(X) RJ45µç¿Ú

2GX16T=2×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 16×10/100Base-T(X) RJ45µç¿Ú

2GX16GE=2×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 16×10/100/1000Base-T(X) RJ45µç¿Ú

4SFP16T=4×100Base-X SFP½Ó¿Ú; 16×10/100Base-T(X) RJ45µç¿Ú

4GX16T=4×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 16×10/100Base-T(X) RJ45µç¿Ú

4GX16GE=4×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 16×10/100/1000Base-T(X) RJ45µç¿Ú

8SFP8T=8×100Base-X SFP½Ó¿Ú; 8×10/100Base-T(X) RJ45µç¿Ú

8GX8T=8×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100Base-T(X) RJ45µç¿Ú

8GX8GE=8×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100/1000Base-T(X) RJ45µç¿Ú

12GX8GE=12×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100/1000Base-T(X) RJ45µç¿Ú

PS1-PS2

L2-L2=24-48VDC (18-72VDC),ÈßÓàÊäÈë

L5-L5=12-24VDC (9-36VDC),ÈßÓàÊäÈë

HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC),µ¥Â·ÊäÈë

PN

Ö§³ÖPROFINET

 

 

Ñ¡¹ºÅä¼þ

Åä¼þÐͺÅ

Åä¼þ˵Ã÷

SFPÄ £¿é

²Î¿¼¹¤Òµ¼¶SFPÄ £¿éÑ¡¹º±í

DT-BGAZ-02

±Ú¹Ò×°Öðå

DT-FCZ-RJ45-01

µ¥¿ÚRJ45·À³¾ÕÖ

KyACB-USB-RJ45

×Ô¶¯ÉèÖñ¸·ÝºÍ»Ö¸´¹¤¾ß

 

×ÊÁÏÏÂÔØ
ÍøÕ¾µØͼ