Aquam8112-1U
12G¶Ë¿Ú¶þ²ã¹ÜÀíÐ͹¤ÒµÒÔÌ«Íø½»Á÷»ú
²úÆ·¼ò½é

Aquam8112-1U»®·ÖÊÇרΪ¹ìµÀ½»Í¨ÐÐÒµÉè¼ÆµÄ¶þ²ãÍø¹ÜÐ͹¤ÒµÒÔÌ«Íø½»Á÷»ú£¬ Ö§³Ö 12¸öǧÕ×ÒÔÌ«Íø½Ó¿Ú£¬ÆäÖÐ4 ¸öΪǧÕ×Bypass¶Ë¿Ú£¬PoEÐͺſɰüÀ¨8¸öǧÕ×»ò°ÙÕ×PoEÍø¿Ú¡£²úƷΪ1U»ú¼ÜʽװÖã¬Ö§³Ö¿í¹æÄ£(-40~+70¡æ)µÄ¿É²Ù×÷ζÈ£¬Öª×ã EN50155¡¢EN50121µÈ¹ìµÀ½»Í¨ÐÐÒµ±ê×¼µÄÒªÇó¡£Ö§³ÖÈ«¶Ë¿Ú M12½Ó¿ÚÐÎʽ£¬°ü¹Ü¶Ë¿ÚÅþÁ¬¼°Õû»úµÄÃÜ·âÐÔºÍÀο¿ÐÔ£¬ÓÈÆäÊʺÏÓÐÇ¿ÁÒµÄÕñ¶¯ºÍ¹¥»÷µÄÓ¦Óó¡¾°¡£Aquam8112-1U ÒÔÌ«Íø½»Á÷»úÖ§³ÖÓÃÓÚ IP µØÖ·×Ô¶¯·ÖÅÉµÄ DHCP ЭÒé¼°¶àÖÖ DHCP option Ñ¡Ï²¢ÇÒÖ§³Ö DRP ºÍ RSTP »·ÍøÈßÓàЭÒ飬¿ÉÒÔÎÞа×éÍø£¬ÒÔÖª×ãÌú·Êг¡µÄÐèÇó¡£

Òªº¦ÌØÕ÷

¸ÃϵÁÐ×î¶àÖ§³Ö12¸öǧÕ×ÒÔÌ«Íø½Ó¿Ú

Ö§³ÖBypass¹¦Ð§

µçÔ´½Ó¿Ú¼°¶Ë¿ÚÅþÁ¬Æ÷ÐͺÅÖ§³ÖM12

Ö§³ÖDRPºÍRSTP»·ÍøÈßÓà±£»¤

ÇкÏEN50155ºÍEN50121ÐÐÒµ±ê×¼ÒªÇó,רΪ¹ìµÀ½»Í¨Ó¦ÓÃÉè¼Æ

1U»ú¼ÜʽװÖÃ

Ö§³Ö802.3af/at PoE¹©µç£¬×î´óÊä³ö¹¦ÂÊ60W

ÐÔÄܲÎÊý
Èí¼þ¹¦Ð§
Ö§³ÖЭÒé IEEE 802.3ab£¬ÓÃÓÚǧÕ×ÒÔÌ«Íø
IEEE 802.3u,ÓÃÓÚ°ÙÕ×ÒÔÌ«Íø
IEEE 802.1Q£¬ÓÃÓÚVLAN ±ê¼Ç
IEEE 802.1p£¬ÓÃÓÚQoS·þÎñÆ·¼¶
½»Á÷»ú¹¦Ð§ Ö§³Ö¾²Ì¬VLAN£¬²»ÉÙÓÚ64¸ö£¬±àºÅ¹æÄ£1-4094
Ö§³Ö8K MACµØÖ·±í
»·Íø×ÔÓúʱ¼ä²»´óÓÚ50ms
QOSÉèÖò»ÉÙÓÚ6¸öÐÐÁÐ
Ö§³Ö¶Ë¿ÚÁ÷¿Ø £¬¶Ë¿Ú×Ô˳Ӧ
Ö§³Ö¹ã²¥¡¢×é²¥¡¢Î´Öªµ¥²¥·ç±©ÒÖÖÆ
Ö§³Ö¾²Ì¬ºÍ¶¯Ì¬MACµØÖ·ºÍMACµØÖ·ÀÏ»¯
ʱÖÓ¹ÜÀí Ö§³ÖSNTP client
Ö§³ÖNTP client
ÈßÓàÊÖÒÕ Ö§³ÖRSTP (Rapid Spanning Tree Protocol)
Ö§³ÖDRP£¬×ÔÓúʱ¼ä<50ms
Ö§³ÖÁ´Â·¾ÛºÏ(LACP, IEEE802.3ad)
×é²¥ÊÖÒÕ Ö§³ÖIGMP snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
ÍøÂçÇå¾² Ö§³ÖIEEE 802.1x(Éí·ÝÈÏÖ¤ºÍÊÚȨ)
Ö§³ÖHTTPs/SSL
Ö§³ÖSSH
Ö§³ÖÍâµØRADIUS server, Ò²Ö§³Ö¶ÔÍⲿµÄRADIS Serverת·¢Éí·ÝÈÏÖ¤ÐÅÏ¢
Ö§³ÖTACACS+
¹ÜÀíÓëά»¤ Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨
Ö§³Öͨ¹ýÍø¹ÜϵͳԶ³ÌÅúÁ¿ÉèÖÃ
Ö§³ÖSNMP¹ÜÀí, Ö§³ÖSNMPv1/v2c/v3
Ö§³ÖTCP/UDP, Ping,
Ö§³Öͨ¹ýFTP/TFTP/HTTP/HTTPs¾ÙÐÐÈí¼þºÍÉèÖõÄÉÏ´«ÏÂÔØ
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖLLDPºÍLLDP MIB£¨802.1ab£©
Õï¶ÏÊÖÒÕ Ö§³ÖIP/MAC³åÍ»¸æ¾¯, µçÔ´¸æ¾¯, ¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯
Ö§³ÖÈÕÖ¾¹¦Ð§
IP¹ÜÀí Ö§³ÖIPv4
Ö§³ÖDHCP server/option12
Ö§³ÖDHCP Relay Agent Information Option
Ö§³ÖDHCP Client
Ö§³ÖARP
·þÎñÖÊÁ¿¹ÜÀí Ö§³ÖACL
Ö§³Ö»ùÓڶ˿ں͵ØÖ·µÄÊý¾ÝÁ÷¿ØÖƺÍÏÞÖÆ
Ö§³Ö802.1p TOS/DiffServ, Ö§³ÖSP, WRRÐÐÁе÷Àí
²úÆ·¹æ¸ñ
LED PWRָʾµÆ£º
ÂÌÉ«³£ÁÁ£ºµçÔ´ÊäÈëÕý³££»
Ã𣺵çÔ´ÊäÈëÒì³£
RUNָʾµÆ£º
ÂÌÉ«³£ÁÁ£ºÏµÍ³Òì³£»òÕýÔÚÆô¶¯
ÂÌÉ«ÉÁ×Æ£ºÏµÍ³Õý³£
AlarmָʾµÆ£º
ºìÉ«³£ÁÁ£ºÏµÍ³¹ÊÕÏ
Ãð£ºÏµÍ³Õý³£
ǧÕ×/°ÙÕ×½Ó¿ÚָʾµÆ£º
ÂÌÉ«³£ÁÁ£ºÇ°Ãæ°å¶Ë¿ÚÅþÁ¬
ÂÌÉ«ÉÁ×Æ£ºÇ°Ãæ°å¶Ë¿ÚÓÐÊý¾ÝÊÕ·¢
Ãð£ºÇ°Ãæ°å¶Ë¿Ú¶Ï¿ª
»ú¿Ç ½ðÊô
É¢ÈÈ ÎÞµçÉÈ
·À»¤Æ·¼¶ IP40
³ß´ç £¨W¡ÁH¡ÁD£© 440mm x 44mm x 256.6.6mm
ÖØÁ¿(Kg) <4.27kg
×°Ö÷½·¨ 1U»ú¼Ü×°ÖÃ
¶î¶¨µçѹֵ 110VDC
ÊäÈëµçѹ¹æÄ£ 77~137.5VDC
¹¦ÂÊ 9.5W
µçÔ´¶Ë×ÓÀàÐÍ M12
ÈßÓàµçÔ´ Ö§³Ö
·´½Ó¡¢¹ýÔر£»¤ Ö§³Ö
ÐÐÒµ±ê×¼ EMI: FCC CFR47 Part 15
EMS: EN50121
·À»ð: EN45545-2(pending)
Çå¾²: EN62368-1(pending)
¹ìµÀ½»Í¨£ºEN50155¡¢EN50121-1¡¢EN50121-4(pending)
»úе: IEC61373 (Õñ¶¯ºÍ¹¥»÷)(pending)
·À»¤Æ·¼¶: IP40 Based on EN 60529(pending)
ΣÏÕÖÊÁÏ: 2002/95/EG of the EU (RoHS)
Öʱ£ ±£ÐÞÆÚ: 5Äê
ÇéÐÎ ÊÂÇéζÈ: -40¡ãC to +70¡ãC
´æ´¢Î¶È: -40¡ãC to +85¡ãC
Ïà¶Ôʪ¶È: 5 to 95% (ÎÞÄý¶)
»úе³ß´ç

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

ÍƼöÐͺÅ

 

Aquam8112-1U-B-4GE8GP-H6-H6

¶þ²ã1U»ú¼Üʽ³µÔؽ»Á÷»ú£¬4¸öǧÕ×Bypass M12ÒÔÌ«Íøµç¿Ú£¬8¸öǧÕ×POE M12ÒÔÌ«Íøµç¿Ú£¬110VDC¹©µç

Aquam8112-1U-B-12GE-H6-H6

¶þ²ã1U»ú¼Üʽ³µÔؽ»Á÷»ú£¬4¸öǧÕ×Bypass M12ÒÔÌ«Íøµç¿Ú£¬8¸öǧÕ× M12ÒÔÌ«Íøµç¿Ú£¬110VDC¹©µç

Aquam8112-1U-B-4GE8T-H6-H6

¶þ²ã1U»ú¼Üʽ³µÔؽ»Á÷»ú£¬4¸öǧÕ×Bypass M12ÒÔÌ«Íøµç¿Ú£¬8¸ö°ÙÕ× M12ÒÔÌ«Íøµç¿Ú£¬110VDC¹©µç

 

¿ÉÑ¡Åä¼þ

SAP±àÂë Accessory Model Description Note
107100246 M12-A-4P-F-Crimp M12ĸͷÅþÁ¬Æ÷, A-Coding, 4 Pin, ѹ½Ó µçÔ´ÅþÁ¬Æ÷
302182000 DT-XL-PWR-M12-XXX-3m µçÔ´½Ó¿ÚÅþÁ¬ÏßM12 toÂã¶Ë£¬3m µçÔ´ÌÖÂÛÏßÀÂ(º¬M12ÅþÁ¬Æ÷)
107100244 M12-D-4P-M-Crimp M12¹«Í·ÅþÁ¬Æ÷, D-Coding, 4 Pin, ѹ½Ó 10/100Base-TX¶Ë¿ÚÅþÁ¬Æ÷
107100245 M12-X-8P-M-Crimp M12¹«Í·ÅþÁ¬Æ÷, X-Coding, 8 Pin, ѹ½Ó 10/100/1000Base-TX¶Ë¿ÚÅþÁ¬Æ÷
107100129 M12-A-4P-M M12¹«Í·ÅþÁ¬Æ÷, A-Coding, 4 Pin Console/USBÅþÁ¬Æ÷

 

×ÊÁÏÏÂÔØ
ÍøÕ¾µØͼ