SICOM2000-L2-2G2GE20TÊÇרΪǶÈëʽ¼¯³ÉÓ¦Óÿª·¢µÄ¶þ²ãÍø¹ÜÐÍǶÈëʽ¹¤ÒµÒÔÌ«Íø½¹µã½»Á÷Ä£¿é£¬×î´óÖ§³Ö20¸ö°ÙÕ׿ìËÙÒÔÌ«Íø½Ó¿Ú¼°4¸öǧÕ×ÒÔÌ«Íø½Ó¿Ú£¬ÆäÖÐ2¸öΪǧÕ×COMBO¿Ú¡£Ö§³Ö¿í¹æÄ£µÄ¿É²Ù×÷ζȣ¨-40¡æ~70¡æ+£©£¬³ß´çΪ80mmx95mmx16mm(³¤x¿íx¸ß)£¬Êʺ϶à¶Ë¿ÚͨѶ¡¢¸ß¶È¼¯³É»¯µÄÓ¦ÓõÄÒªÇó¡£
SICOM2000-L2-2G2GE20TϵÁй¤ÒµÒÔÌ«Íø½»Á÷Ä£¿éÖ§³ÖDRPºÍRSTP»·ÍøÈßÓàÐÒ飬¿ÉÒÔÎÞа×éÍø£¬²¢Öª×ã<20msÍøÂç¶ÏÏ߻ָ´Ê±¼ä¡£³ýÒÔÌ«Íø½Ó¿ÚÍ⣬¸ÃÄ£¿é»¹Ìṩ15¸öGPIO½Ó¿Ú¿Éͨ¹ýÏÂÁîÐоÙÐÐÉèÖü°ÅÌÎÊ£¬ÒÔÖª×ã²î±ðÓ¦Óó¡¾°ÐèÒª¾ÙÐÐ״̬ÅÌÎÊ»òÊä³öµÄÐèÇó¡£
¸ÃϵÁÐ×î¶àÖ§³Ö2¸öǧÕ×µç¿Ú+2¸öǧÕ×Combo¿Ú+20¸ö°ÙÕ×µç¿Ú
Ö§³ÖÓ²¼þ¸´Î»¹¦Ð§
ÈÕÖ¾Óëϵͳ³ÌÐòʹÓÃ×ÔÁ¦FLASHÌá¸ß²úÆ·ÎȹÌÐÔ
*Ìṩ15¸öGPIO½Ó¿Ú
Ö§³ÖDT-RingÐÒé×å,RSTP/MSTP,DRP»·ÍøÈßÓà
* ÈçÐè½ç˵GPIOÇëÁªÏµ×ðÁú¿Ê±
²úÆ·¹æ¸ñ | |
ÐÐÒµ±ê×¼ | EMI FCC CFR47 Part 15,EN55022/CISPR22,Class A EMS IEC61000-4-2 (ESD) ¡À6kV (contact), ¡À8kV (air) IEC61000-4-3£º(RS) 20V/m (80MHz-2GHz) IEC61000-4-4£º(EFT) Power Port: ¡À2kV; Data Port: ¡À2kV IEC61000-4-5£º (Surge) Power Port: ¡À1kV/DM, ¡À2kV/CM IEC61000-4-6£º(CS)10V (150kHz-80MHz) IEC61000-4-8£º(Power frequency magnetic field)50Hz 100A/m IEC61000-4-9£º(Pulsed magnetic field )300A/m IEC61000-4-29£º(Voltage Short interruptions) 10ms 100% »úе IEC61373(Õñ¶¯ºÍ¹¥»÷) IEC60068-2-32(×ÔÓɵøÂä) |
ÇéÐÎ | ÊÂÇéζȣº-40¡æ¡«+70¡æ+ Öü´æζȣº-40¡æ¡«+85¡æ Ïà¶Ôʪ¶È£º5¡«95%ÎÞÄý¶ |
»úе½á¹¹ | ³ß´ç£º95mm x 80mm x 15.9mm ×°Ö÷½·¨£ºÇ¶Èëʽ |
ָʾµÆ | ÔËÐÐָʾµÆ:Run »·ÍøָʾµÆ:Ring,Master µçԴָʾµÆ:PWR ½Ó¿ÚָʾµÆ:Link/ACT |
½Ó¿Ú | ǧÕ׶˿ڣº10/100/1000Base-T(X) °ÙÕ׶˿ڣº10/100Base-T(X) Console¿Ú£ºRS232 ¸´Î»°´Å¥ µçÔ´Êä³ö£º3.3VDC½Ó¿Ú LED£º28·LED¿ØÖÆ½Ó¿Ú GPIO£º15·½Ó¿Ú |
½»Á÷ÊôÐÔ | ÓÅÏȼ¶ÐÐÁУº8 VLANÊý£º4K VLAN ID£º1¡«4093 ×é²¥×éÊý£º64 MAC±í£º16K °ü»º³åÇø£º4Mbit ×î´ó°üת·¢ÂÊ£º17.9Mpps ½»Á÷ÑÓ³Ù£º<10us |
±ê×¼ | IEEE 802.3i(10Base-T) IEEE 802.3u(100Base-T) IEEE 802.3ab(1000Base-T) IEEE 802.3x(Á÷¿Ø) IEEE 802.1p(ÓÅÏȼ¶) IEEE 802.1Q(VLAN) IEEE 802.1s£¨MSTP£© IEEE 802.1w£¨RSTP£© IEEE 802.1X£¨»á¼û¿ØÖÆÐÒ飩 |
Èí¼þ¹¦Ð§ | |
µçÔ´ | ÊäÈëµçѹ£º5VDC£¨µçѹ²¨¶¯5%£© ¹¦ºÄ£ºÐ¡ÓÚ20W |
ʱÖÓ¹ÜÀí | Ö§³ÖSNTP client Ö§³ÖPTPv2 TCģʽ |
IP¹ÜÀí | Ö§³ÖDHCP server/client/server option 82 |
¹ÜÀíÓëά»¤ | Ö§³ÖConsole,Telnet,WEB¹ÜÀí·½·¨ Ö§³ÖSNMPv1/v2c/v3,¿Éͨ¹ýKyvision¼¯ÖйÜÀí Ö§³ÖFTP/TFTPÎļþ´«Êä¼°Èí¼þÉý¼¶ Ö§³ÖRMON Ö§³ÖIP/MAC³åÍ»¸æ¾¯,µçÔ´¸æ¾¯,¶Ë¿Ú¸æ¾¯,»·¸æ¾¯ Ö§³Ö¶Ë¿Ú¾µÏñ Ö§³ÖSyslog Ö§³ÖLLDP |
·þÎñÖÊÁ¿¹ÜÀí | Ö§³ÖACL Ö§³Ö802.1pºÍTOS/DiffServ,Ö§³ÖSP,WRRÐÐÁе÷Àí |
Çå¾²ÊÖÒÕ | Ö§³ÖIEEE 802.1x Ö§³ÖHTTPs/SSL, SFTP Client Ö§³ÖSSH Ö§³ÖRADIUS Ö§³ÖTACACS+ Ö§³ÖÓû§·Ö¼¶ |
×é²¥ÊÖÒÕ | Ö§³ÖIGMP-snooping Ö§³ÖGMRP Ö§³Ö¾²Ì¬×é²¥ |
ÈßÓ๦Ч | Ö§³ÖDT-ring, DT-ring+, DT-VLANÐÒé×壬×ÔÓúʱ¼ä<50ms Ö§³ÖDRP/DHP, ×ÔÓúʱ¼ä<20ms Ö§³ÖRSTP/MSTP |
½»Á÷¹¦Ð§ | Ö§³ÖVLAN,PVLAN Ö§³ÖGVRP Ö§³Ö¶Ë¿Ú¾ÛºÏ Ö§³ÖLACP Ö§³Ö¶Ë¿ÚÁ÷¿Ø Ö§³Ö¶Ë¿ÚÏÞËÙ,¹ã²¥·ç±©ÒÖÖÆ |
ÅþÁ¬Æ÷£º2 x SAMTEC “SFM-150-02-S-D-A-K-TR”¡£ÅþÁ¬Æ÷×°Öø߶È6.35m£¬É¢ÈÈÆ÷×°Öÿ׿׾¶3.25mm¡£
²úÆ·Ñ¡ÐÍ
²úÆ·ÐͺŠ| Êä³ö½Ó¿Ú | ±¸×¢ |
SICOM2000-L2-C-2G2GE20T | 2¸öǧÕ×Combo¿Ú£¬2¸öǧÕ×µç¿Ú£¬20¸ö°ÙÕ×µç¿Ú | Èý·ÀÍ¿¸² |
SICOM2000-L2-2G2GE20T | 2¸öǧÕ×Combo¿Ú£¬2¸öǧÕ×µç¿Ú£¬20¸ö°ÙÕ×µç¿Ú |